An A1 grade fireproof board is a non-combustible or highly fire-resistant building panel developed for interior wall cladding, partitions, ceilings and other architectural applications where fire safety is a critical project requirement.
Under the European reaction-to-fire classification system, products classified as EN 13501-1 Class A1 make no significant contribution to fire development under the specified test conditions. Buyers should always confirm the applicable product model, thickness, surface finish, test standard and certification report before specifying a board for a project.
POLYBETT supplies decorative fireproof wall boards with inorganic core materials and customizable surface designs. The panels are suitable for hospitals, schools, laboratories, nursing homes, transportation facilities, commercial buildings and other public interiors requiring a combination of fire safety, durability, cleanability and decorative performance.

POLYBETT fireproof boards are designed for architectural projects that require a durable decorative surface combined with an inorganic or flame-retardant board structure. Depending on the selected model, the panel can incorporate a decorative melamine or HPL surface, fireproof layers and an inorganic core.
The product range includes solid-color fireproof panels, wood-grain wall boards, stone-effect panels, hospital wall cladding and customizable decorative boards for public and commercial interiors.
| Item | Typical Option |
|---|---|
| Product name | A1 Grade Fireproof Board / Decorative Fireproof Wall Panel |
| Core material | A-grade inorganic core, mineral-based core or fire-retardant substrate, depending on the model |
| Surface material | Decorative melamine surface, HPL surface or customized decorative layer |
| Common board sizes | 1200 × 2400 mm, 1200 × 2800 mm and 1200 × 3000 mm |
| Thickness range | Commonly 0.6–30 mm; available thickness depends on the selected product structure |
| Colors | Solid colors, wood grain, stone patterns and customized decorative designs |
| Surface finishes | Matte, texture, glossy and project-specific finishes |
| Fire performance | Available fire-resistant or non-combustible configurations; confirm the applicable test report for the required market |
| Optional properties | Antibacterial surface, moisture resistance, abrasion resistance, stain resistance and impact resistance |
| Customization | Size, thickness, color, surface texture, edge processing and packaging |
| MOQ and lead time | Confirmed according to product model, dimensions, finish and order quantity |
An independently tested A1 non-combustible board is designed to make no significant contribution to fire growth under the relevant reaction-to-fire test conditions. The exact fire classification must be verified through the test report supplied for the selected board model.
Decorative HPL or melamine surfaces provide a wide selection of solid colors, wood grains, stone patterns and textures. This allows architects to combine fire-safety requirements with interior design specifications.
The smooth, non-porous decorative surface helps simplify daily cleaning and maintenance. Selected models can be supplied with antibacterial or enhanced hygiene-related surface options for hospitals, clinics, laboratories and public facilities.
Fireproof decorative wall panels can provide better resistance to scratches, abrasion and everyday impact than many painted wall surfaces. This makes them suitable for corridors, waiting areas, classrooms and other high-traffic interiors.
Moisture-resistant board configurations are available for interior spaces that require frequent cleaning or experience changing humidity levels. Water resistance should be confirmed according to the board core, surface, edge treatment and installation system.
Board thickness, panel dimensions, surface color, texture and packaging can be customized for distributors, contractors, wall-system manufacturers and project buyers.
POLYBETT provides multiple decorative fireproof board options for different architectural and interior applications:
A1 Level Fireproof Hospital Wall Panel for healthcare facilities, corridors and public interiors.
Class A Fireproof HPL Phenolic Laminate Wall Panel for durable decorative wall-cladding projects.
Flexible Wood-Grain Fireproof HPL Wall Paneling for warm decorative interior designs.
Solid-Color Hospital Wall Panels for clean, modern healthcare and institutional environments.
Flame-Retardant Hospital Wall Cladding System for project-specific wall protection requirements.
| Application | Typical Requirements |
|---|---|
| Hospitals and clinics | Fire safety, easy cleaning, antibacterial surface options and impact resistance |
| Laboratories and clean areas | Smooth surfaces, stain resistance, cleanability and controlled joint design |
| Schools and daycare centers | Durability, easy maintenance, decorative colors and resistance to daily wear |
| Nursing homes | Hygienic surfaces, impact resistance and coordinated interior design |
| Airports and railway stations | Fire performance, high-traffic durability and low-maintenance wall protection |
| Hotels and commercial buildings | Decorative flexibility, fire safety and long-term surface performance |
| Office corridors and public spaces | Scratch resistance, stain resistance and easy replacement of individual panels |
| Fire stations and utility buildings | Fire-resistant materials, durable finishes and practical installation systems |
International buyers often use the terms “A1 fireproof board,” “Class A fireproof panel” and “fire-rated wall board” interchangeably. However, these terms can refer to different test methods and performance criteria.
| Term | What It Generally Describes | What Buyers Should Verify |
|---|---|---|
| EN 13501-1 Class A1 | European reaction-to-fire classification for non-combustible construction products | Product name, thickness, substrate, surface configuration and valid classification report |
| ASTM E84 Class A | Surface-burning classification based on flame-spread and smoke-developed indexes | Reported index values and whether the tested configuration matches the supplied panel |
| ASTM E136 | Assessment of whether a material behaves as non-combustible under specified test conditions | Test laboratory, specimen construction and applicable product model |
| 60-, 90- or 120-minute fire resistance | Performance of a complete wall, ceiling, partition or structural assembly during a fire-resistance test | Complete system design, framing, insulation, joints, fixings, penetrations and installation details |
A board with an A1 reaction-to-fire classification does not automatically provide a specific fire-resistance duration when installed in any wall system. Project designers should evaluate the complete tested assembly and local building-code requirements.
Confirm the required fire standard. Specify whether the project requires EN 13501-1 A1, ASTM E84 Class A, ASTM E136 or a tested fire-resistance assembly.
Define the installation area. Indoor wall cladding, ceilings, partitions, corridors and healthcare interiors may require different board structures and installation details.
Select the required board thickness. Thickness affects weight, rigidity, impact resistance, processing and compatibility with the supporting framework.
Evaluate moisture and cleaning requirements. Hospitals, laboratories and public facilities may need enhanced water resistance, sealed edges and chemical-compatible cleaning surfaces.
Choose the decorative finish. Match solid colors, wood grains, stone patterns and surface textures to the architectural design.
Review processing and fixing methods. Confirm cutting tools, drilling requirements, fastener spacing, adhesive compatibility, joint profiles and edge-treatment methods.
Request technical documents. Ask for the fire-test report, technical data sheet, installation instructions, sample, color chart and other project-specific certificates before ordering.
The final installation method depends on the board type, wall substrate, supporting framework and required fire-rated system. Installation should follow the approved project drawings, local regulations and the instructions supplied for the selected panel.
Store panels flat in a dry, ventilated location before installation.
Confirm that the wall substrate or supporting frame is level, stable and suitable for the panel weight.
Use suitable cutting and drilling tools to reduce edge chipping and excessive dust.
Maintain the specified panel joints, expansion allowances and edge clearances.
Use compatible fasteners, adhesives, trims and joint-sealing materials.
Seal penetrations and junctions according to the tested fire-rated wall-system design.
Protect the decorative surface during transportation, cutting and installation.
For routine maintenance, remove dust with a soft cloth and clean the surface using water or a mild neutral cleaning solution. Avoid steel wool, aggressive abrasive pads and unapproved chemicals that may damage the decorative finish.
For hospitals, laboratories and other controlled environments, confirm the compatibility of disinfectants with the selected surface before establishing a cleaning protocol.
Multiple fireproof decorative board structures for hospitals, schools and commercial interiors.
Custom sizes, thicknesses, colors, textures and decorative patterns.
Solid-color, wood-grain, stone-effect and project-specific surface options.
Support for OEM, ODM, distributor and construction-project requirements.
Product samples, color matching and technical-document support.
Export packaging and order coordination for international buyers.
A1 is the highest reaction-to-fire classification for construction products under EN 13501-1. It indicates that the tested product does not make a significant contribution to fire development under the relevant test conditions. Buyers should request the classification report for the exact board model and thickness.
No. EN 13501-1 Class A1 and ASTM E84 Class A are based on different test standards and classification criteria. A product should not be described as meeting both standards unless corresponding test reports are available.
No. A1 normally describes the reaction-to-fire performance of the material. A two-hour fire-resistance rating applies to a complete tested wall assembly, including the board, frame, insulation, joints, fasteners and penetrations.
Yes. Suitable fireproof decorative board models can be used in hospital corridors, patient areas, clinics, laboratories, nursing homes and other healthcare interiors. The selected panel should meet the project’s fire, hygiene, impact-resistance and cleaning requirements.
Antibacterial surface options are available for selected products. For healthcare or clean-area projects, request the applicable antibacterial test method, test report and cleaning recommendations before specification.
Common board sizes include 1200 × 2400 mm, 1200 × 2800 mm and 1200 × 3000 mm. Depending on the product model, thicknesses can commonly range from approximately 0.6 mm to 30 mm. Customized dimensions can be discussed for project orders.
Yes. Available designs can include solid colors, wood grain, stone patterns, matte surfaces, textured finishes and glossy finishes. Custom color matching may be available depending on the order quantity and production requirements.
Water resistance depends on the core material, decorative surface, panel edges and installation system. Some boards offer strong moisture resistance, but buyers should not assume that every fireproof board is suitable for continuous water exposure.
Installation may use mechanical fasteners, profiles, adhesives or a combined wall-cladding system. The correct method depends on the panel thickness, substrate, supporting frame and required fire-rated construction.
Buyers should request the technical data sheet, fire-test or classification report, installation instructions, product sample, color chart and relevant environmental, formaldehyde or antibacterial reports required by the project.
Provide the required fire standard, application, board size, thickness, color, finish, quantity, destination port and any certification requirements. Project drawings or wall-system details can help POLYBETT recommend a more suitable panel configuration.
Sample availability depends on the selected color, finish and board structure. Contact POLYBETT with your project specifications to request samples, technical information and current production details.
Send us your required fire standard, panel dimensions, thickness, surface design, quantity and application. Our team will help you evaluate suitable decorative fireproof board options for your project.
WIDE RANGE COLORS
Contact Us